13,350 EGP Inc. VAT
Product successfully added to the Quote List
SKU
SWL2500E
Categories Batteries, VRLA Batteries, Yuasa
Tags High Rate VRLA Battery, Rechargeable Lead Acid battery, SWL2500E, Yuasa, Yuasa Battery, Yuasa SWL2500E

SRT3000XLI | APC Smart UPS Online SRT 3kVA1 × 132,000 EGP
SRT5KXLI | APC Smart UPS Online SRT 5kVA1 × 180,000 EGP
E3SUPS20KHB1 | SE Easy UPS 3S 20 kVA 400V 3:3 UPS1 × 370,000 EGP13,350 EGP Inc. VAT
| Overview | |
| Presentation | SWL2500E (12V 93.6Ah) Yuasa High Rate VRLA Battery Safety Installation: Can be installed and operated in any orientation except permanently inverted. Handles: Batteries must not be suspended by their handles (where fitted). Vent valves: Each cell is fitted with a low pressure release valve to allow gasses to escape and then reseal. Gas release: VRLA batteries release hydrogen gas which can form explosive mixtures in the air. Do not place inside a sealed container. Recycling: YUASA’s VRLA batteries must be recycled at the end of life in accordance with local and national laws and regulations. |
| Lead time | Usually in Stock |
| Specifications | |
| Nominal voltage (V) | 12 |
| 10m rate Constant Power (Typ) to 9.6V at 20°C (W/Block) | 2940 |
| 10m rate Constant Power (Typ) to 1.6V/cell at 20°C (W/Cell) | 490 |
| 10-hr rate Capacity to 1.8V/Cell at 20°C (Ah) | 91.4 |
| 20-hr rate Capacity to 1.75V/Cell at 20°C (Ah) | 93.6 |
| Dimensions | |
| Length (mm) | 305 (±3) |
| Width (mm) | 168 (±2) |
| Height (mm) | 224.5 (±1) |
| Mass (kg) | 33 |
| Terminal Type | |
| Threaded terminal – (M=Male or F=Female) Torque (Nm) | M6 (F) 4.8 |
| Operating Temperature Range | |
| Storage (in fully charged condition) | -20°C to +50°C |
| Charge | -15°C to +50°C |
| Discharge | -20°C to +60°C |
| Storage | |
| Capacity loss per month at 20°C (% approx.) | 3 |
| Case Material | |
| Standard | ABS (UL94:HB) |
| FR version available | UL94:V0 |
| Charge Voltage | |
| Float charge voltage at 20°C (V)/Block | 13.65 (±1%) |
| Float charge voltage at 20°C (V)/Cell | 2.275 (±1%) |
| Float Chg voltage tmp correction factor from std 20°C (mV) | -3 |
| Cyclic (or Boost) charge Voltage at 20°C (V)/Block | 14.5 (±3%) |
| Cyclic (or Boost) charge Voltage at 20°C (V)/Cell | 2.42 (±3%) |
| Cyclic Chg voltage tmp correction factor from std 20°C (mV) | -4 |
| Charge Current | |
| Float charge current limit (A) | No limit |
| Cyclic (or Boost) charge current limit (A) | 22.5 |
| Maximum Discharge Current | |
| 1 second (A) | 1000 |
| 1 minute (A) | 500 |
| Short-Circuit Current & Internal Resistance | |
| Internal resistance – according to EN IEC 60896-21 (mΩ) | 6.5 |
| Short-Circuit current – according to EN IEC 60896-21 (A) | 2258 |
| Impedance | |
| Measured at 1 kHz (mΩ) | 4 |
| Design Life & Approvals | |
| EUROBAT Classification: Long life | 10 to 12 years |
| Yuasa design life at 20°C (yrs) | up to 10 years |
Sale!
Sale!
Sale!
Sale!
Sale!